    Home»Science»Smart Flow Cytometer Uses Clogging to Its Advantage
    Science

    Smart Flow Cytometer Uses Clogging to Its Advantage

    By Nara Institute of Science and TechnologySeptember 16, 2025No Comments4 Mins Read
    Facebook Twitter Pinterest Telegram LinkedIn WhatsApp Email Reddit
    Share
    Facebook Twitter LinkedIn Pinterest Telegram Email Reddit
    Dynamically Adjusting the Height of Microfluidic Channels Improves Impedance Flow Cytometry Performance
    Impedance flow cytometry measurements are adversely affected by the distance between the analyte and the sensing electrodes. By slightly squeezing the microfluidic channel, adapts the channel’s height to a desired particle size, and improves variability and sensitivity of detection. This innovative solution leverages the ‘clogging phenomena,’ which is typically a problem in flow cytometry systems, to enhance their analytical performance. Credit: Dr. Yalikun Yaxiaer and Mr. Trisna Julian from Nara Institute of Science and Technology, Japan

    Japanese researchers have created a dynamic microfluidic channel that greatly enhances the performance of flow cytometers.

    Flow cytometry has enabled many breakthroughs in medicine and drug discovery. The technique examines single cells by detecting the fluorescence from their chemical tags as the cells pass through a laser beam. Most instruments include a microfluidic channel, a narrow passage that regulates the flow of these tagged analytes. Because it allows rapid counting and analysis at the single-cell level, flow cytometry has become a cornerstone of modern biomedical research.

    A powerful alternative, impedance flow cytometry, replaces the laser with electrodes that sense changes in electrical impedance (the total resistance of electrical equipment to alternating current) as cells or particles move through the microfluidic channel. This approach removes the need for fluorescent tags, which are often expensive and time-consuming to use. However, its sensitivity can be limited and its readouts inconsistent, since the distance between flowing cells and the electrodes varies with channel height and particle size.

    A New Adaptive Solution from NAIST

    To fill this gap, a research team led by Associate Professor Yalikun Yaxiaer from Nara Institute of Science and Technology (NAIST), Japan, developed an innovative low-cost platform to overcome these limitations. Their paper, published in the journal Lab on a Chip, was co-authored by Mr. Trisna Julian, Dr. Naomi Tanga, Professor Yoichiroh Hosokawa from NAIST, and others.

    The team’s design goal was straightforward; they aimed to dynamically adjust the channel height depending on particle size. They realized this by attaching a metal probe to the vertical axis of an XYZ stage—a laboratory device that enables highly precise movements in three dimensions. By controlling the vertical position of the probe, they used its thin tip to press against the top of the 30-micrometer-high microfluidic channel of the flow cytometer. This compression squeezed the channel slightly, altering its height on demand.

    Through experiments and simulations, the team showed that enabling the flowing particles to travel closer to the sensing electrodes by reducing the channel’s height led to a remarkable increase in the platform’s sensitivity and accuracy. They achieved a three-fold amplification of the impedance signal by reducing the channel height by one-third, while also reducing the signal variability to half, allowing them to easily distinguish between multiple cells of different sizes.

    Turning Clogging into an Advantage

    Notably, by introducing a camera and an object-detection algorithm, the researchers found a way to leverage clogging (unwanted deposition of particles that prevents further passage of analytes) as a strategy to optimize the platform’s performance. “Our system deliberately induces a critical constriction by deforming the channel to maximize sensitivity. However, this deformation can be released just before actual clogging occurs,” explains Dr. Yaxiaer. “Thus, our approach acts like a smart microchannel that harnesses and controls the clogging phenomena.”

    Overall, this study establishes a much-needed foundation for the standardization of adaptive impedance flow cytometry, paving the way for its integration into clinical and research contexts where precise cell analyses are required.

    “Our findings underscore the potential for a universal, high-performance impedance flow cytometry platform—one that is simple, clog-resistant, and adaptable for a wide range of biomedical applications,” concludes Dr. Yaxiaer. Collaborating with medical institutions could transform this innovative platform into a diagnostic device for point-of-care testing, and could also be leveraged for drug development and testing.

    Reference: “A long-term universal impedance flow cytometry platform empowered by adaptive channel height and real-time clogging-release strategy” by Trisna Julian, Tao Tang, Naomi Tanga, Yang Yang, Yoichiroh Hosokawa and Yaxiaer Yalikun, 26 August 2025, Lab on a Chip.
    DOI: 10.1039/D5LC00673B

    Never miss a breakthrough: Join the SciTechDaily newsletter.

    Biomedical Engineering Biotechnology Cells Nara Institute of Science and Technology
    Share. Facebook Twitter Pinterest LinkedIn Email Reddit

    Related Articles

    Amazing New Material Combines Wood Fibers and Spider Silk

    Silk Fibers May Represent Natural Metamaterials, Capable of light Confinement

    Advanced Chemical Oscillator Offers New Level of Molecular Control

    Genetically Altered Organism Could Potentially Turn Almost Any Source of Carbon Into Fuel

    Nanoparticle Delivers a Combination of Therapeutic Agents to Tumor Sites

    Single Cancer Cells Often Split into Three or More Daughter Cells

    Scientists Reveal the Structure of Bacterial Injection Needles at Atomic Resolution

    Bioengineers Develop Deformability Cytometer to Help Diagnose Disease

    UCLA Discovery Suggests a Mechanism and Design Principle for the Engineering of Tissue

    Leave A Reply Cancel Reply

    • Facebook
    • Twitter
    • Pinterest
    • YouTube

    Don't Miss a Discovery

    Subscribe for the Latest in Science & Tech!

    Trending News

    Does Space-Time Really Exist?

    Vitamin D May Help Slow Aging, Study Finds

    Universe’s First Magnetic Fields Were As Weak as Human Brain Waves

    “Rogue” DNA Rings Expose Brain Cancer’s Earliest Secrets

    “Like Nothing Anyone Has Ever Seen Before” – Bizarre Supernova Stuns Scientists

    NASA Detects New Interstellar Visitor to Our Solar System: Could It Be an Alien Probe?

    For the First Time in 40 Years, Panama’s Ocean Lifeline Has Vanished

    The Newly Found Bone Switch That Could Stop Osteoporosis

    Follow SciTechDaily
    • Facebook
    • Twitter
    • YouTube
    • Pinterest
    • Newsletter
    • RSS
    SciTech News
    • Biology News
    • Chemistry News
    • Earth News
    • Health News
    • Physics News
    • Science News
    • Space News
    • Technology News
    Recent Posts
    • Contrary to Popular Belief, Yoga Isn’t the Best for Your Arteries
    • High-Fiber Diet Eases Alzheimer’s Symptoms by Calming Gut-Brain Axis, Study Finds
    • This Special Diet May Slow Brain Aging, Harvard Study Reveals
    • A Galaxy Warped by Gravity Glows With Baby Stars
    • Strange Mars Mudstones May Hold the Strongest Clues Yet of Ancient Life
    Copyright © 1998 - 2025 SciTechDaily. All Rights Reserved.
    • Science News
    • About
    • Contact
    • Editorial Board
    • Privacy Policy
    • Terms of Use

    Type above and press Enter to search. Press Esc to cancel.